Fire Alarm Control Panel (FACP) SEC1000

Features

  • Up to 120 addresses on one loop;
  • The loop supports class A and Class B types;
  • An easy to read, 4.3’’ color screen LCD with a resolution of 480×272;
  • Zone indicators for 16 zones gives a quick indica-tion of the location of an alarm;
  • Record capacity of 1000 historical events for each of historical fire, historical fault and histori-cal operation;
  • An independently programmable conventional sounder circuit output;
  • Zone test, point test and module start/stop test-ing facilitate the commissioning;
  • Hierarchy management with three access levels;
  • CAN bus for interconnection of up to 20 FACPs;

The purpose of the Fire Alarm Control Panel (FACP) SEC1000 is to monitor input signals, give indications and possibly activate outputs as programmed. SEC1000 is designed to comply with EN 54-2 with
qualities of simple installation, operation and easy maintenance.

 

 

Mains supply

110V/230VAC (-15%, +10%),50Hz/60Hz

Mains fuse

T3.15AL250V

Operating voltage

20 ~ 28VDC

Power rating

Imin=0.45A; Imax.a=1.15A; Imax.b=1.65A

Max. battery supply current

3A (when the Mains is disconnected)

Max. charging current

1A

Max. internal resistance of battery

Battery fuse

F6AL250V

Quiescent current (full loaded)

< 0.4A

S.C.Out (+,-) - Output voltage

20 ~ 28VDC

S.C.Out (+,-) - Max. output current

800mA, 1A S.C.Out+24VK in total

S.C.Out (+,-) - End of line resistor

47K ohm 0.25W

S.C.Out (+,-) - Cable diameter

1mm2~ 2.5mm2

S.C.Out (+,-) - Transmission distance

≤1500m

F.A.Out(+,-) - Output voltage

20 ~ 28VDC

F.A.Out(+,-) - Max. output current

100mA

F.A.Out(+,-) - End of line resistor

47K ohm 0.25W

F.A.Out(+,-) - Cable diameter

1mm2~ 2.5mm2

F.A.Out(+,-) - Transmission distance

≤1500m

FAULT OUT (COM, NO) - Contact capacity

30VDC@2A, 125VAC@0.5A

FAULT OUT (COM, NO) - Cable diameter

1mm2~ 2.5mm2

24VK (+, -) - Output voltage

20 ~ 28VDC

24VK (+, -) - Max. output current

500mA, 1A S.C.Out+24VK in total

24VK (+, -) - Cable diameter

1mm2~ 2.5mm2

Loop Out (+, -) Loop In (+, -) - Output voltage

18.5 ~ 28VDC, pulse

Loop Out (+, -) Loop In (+, -) - Max. output current

500mA

Loop Out (+, -) Loop In (+, -) - Loop type

Class A and Class B

Loop Out (+, -) Loop In (+, -) - Max. Loop length

2000m(Class A)

Loop Out (+, -) Loop In (+, -) - Cable diameter

1mm2~ 2.5mm2

RS-485 - Transmission rate

9600 bps

RS-485 - Transmission distance

≤1000m

RS-485 - Cable diameter

1mm2~ 2.5mm2

RS-485 - Max. number of panels

20

CAN - Transmission rate

Optional: 10K, 20K, 50K and 100K bps

CAN - Transmission distance

≤1000m

Cable diameter

1mm2~ 2.5mm2

Approx. Dimensions of the panel (W×H×D)

400×360×104mm

Approx. weight (without battery)

3.7kg

Operating conditions

Temperature range: -5°C~ 45°C; Max relative humidity: 95% (40°C ± 2°C, no condensation)